Product Description

  • ECG
    Lead type:
    3-lead: I, II, III
  • 5-lead: I, II, III, aVR, aVL, aVF, V
  • Waveform
    3-lead: 1 channel
  • 5-lead: 2-channel
  • Gain: 5mm/mV, 5.0 mm/mV, 10 mm/mV, 20 mm/mV
    Scan speed: 5 mm/s, 25 mm/s, 50 mm/s
    HR
    Measurement and alarm range:
  • Adult: 15 ~ 300 bpm
  • Pediatric/neonate: 15 ~ 350 bpm
  • Resolution: 1 bpm
  • Accuracy: ± 1 % or ± 1 bpm, whichever is greater
  • Alarm error: ± 2 bpm
  • ST-segment detection
    Measurement and alarm range: – 2.0 mV ~ + 2.0 mV
  • Accuracy: – 0.8 mV ~ + 0.8 mV: ± 0.04 mV or ± 10 %, whichever is greater
  • Other range: unspecified
  • Arrhythmia analysis: 13 kinds
    Pacemaker: yes
    RESP
    Measurement mode: R-F(RA-LL) impedance
    Respiration rate:
    Measurement range: 0 ~ 150 rpm
  • Resolution: 1 rpm
  • Accuracy: 7 ~ 150 rpm, ± 2 rpm or ± 2 %, whichever is greater;
  • 0 ~ 6 rpm, unspecified
  • Apnea alarm: 10~ 40 s
    Scan speed: 12.5 mm/s, 25 mm/s
    NIBP
    Measurement mode: Oscillometry
    Working mode: Manual/AUTO/Continuous
    Measurement interval in AUTO mode: 1/ 2 / 3/ 4 / 5 / 10 / 15 / 30 / 60 / 90 / 120 / 240 /480 /960 minutes
    Measurementperiod in Continuous mode: 5 minutes
    Measurement and alarm range: 10~ 270 mmHg
    Resolution: 1mmHg
    Cuff pressure accuracy: ±3 mmHg
    Measurement accuracy:
    Maximal mean deviation: ± 5 mmHg
  • Maximal standard deviation: 8 mmHg
  • Over-pressure protection:
    Adult mode: 297 ± 3 mmHg
  • Pediatric mode: 240 ± 3 mmHg
  • Neonatal mode: 147 ± 3 mmHg
  • SpO2
    Measurement and alarm range: 0~ 100%
    Resolution: 1%
    Measurement accuracy: 70% ~ 100 %: ± 2 %;
    0 % ~ 69 %: unspecified
  • PR
    Measurement and alarm range: 25 ~ 250bpm
    Accuracy: ±2 bpm or ± 2 %, whichever is greater
    TEMP
    Channel: dual-channel
    Measurement and alarm range: 0 ~ 50 ℃
    Resolution: 1℃
    Accuracy: ±1 ℃
    IBP
    Channel: dual-channel
    Label: ART, PA,CVP, RAP, LAP, ICP, P1, P2
    Measurement and alarm range: -10 ~ 300 mmHg
    Resolution: 1 mmHg
    Accuracy: ±2 % or 1 mmHg, whichever is greater
    Power supply: 100 ~ 240 V ~ 50 / 60 Hz (adapter output: DC 12 V)
    Safety class: class I, defibrillation-proof type CF applied part
    Waterproof degree: IP44

 